Pulsed ultraviolet light is able to destruct gaseous toxic compounds of natural and artificial origin (ester, formalin and others) by photooxidating and photodegrading them, in the same time removing any odors in the room.
Shadow areas are treated by moving the unit and activating it in various points of a room (2 or more), so as to cover all existing shadow areas.
Besides, such approach allows for reducing not only the cycle duration in each specific point, but of the whole room treatment due to shorter distance from the lamp to the farthest surface to be treated (especially when decontaminating large rooms).
The units do not replace, but supplement the effect of recirculators. A pulsed unit is intended to prepare rooms for using, simultaneously decontaminating the air and open surfaces.
When a room is in use and the implementation of units is not possible, recirculators are deployed to maintain the required microbial load in the air. Which means that consecutive implementation of recirculators and pulsed UV units considerably increases the disinfection efficiency.
For operating mobile and portable units, no training is needed. All the necessary information can be found in the User’s Guide. If desired, the experts of the manufacturer or a distributor can help with a first launch of the unit, deliver a basic training, and answer any arising questions.
Stationary units are installed and put into operation by the manufacturer’s service department.
The units work in the absence of people. Before the unit launches a disinfection cycle, the irradiation indicator turns on. A sound signal and 20-seconds’ delay allow the personnel to safely leave the room to be treated.
The disinfection cycle can be interrupted by pressing the STOP button on the control panel or on the remote control. If for whatever reason somebody happens to be in the room with a working unit, the first thing to do is to protect the eyes, then leave the room immediately. This has no permanent consequences for human health.
The only consumable item of the units is the lamp (lamp assembly).
This strongly depends on how often the unit is used (once a day, before every surgery, once a week). The practice of usage at healthcare facilities shows, that for a mobile unit the lamp should be replaced once or twice a year, for the portable and stationary units – once every 3 years.
Virusjet ULV fogging or diffuser equipment is used for the application of disinfectants, biocides, fungicides and pesticides. Our ULV fogging machines generate a fog or mist formed of Ultra Low Volume (ULV) droplets between 4-5 microns (μm) in diameter.
Chemical formulations can be applied in dilution ration of 10-99%. No concentrate should be used without dilution in the device.
We offer 24 months Global Warranty for virusjet devices.
Conventional foggers spray larger droplet sizes in between 100-200 microns while virusjet is not an ordinary fogger that makes any smoke show. Instead it sprays between 4-5 microns, while leaving surface dry without any residue and reaches 60m distance*
Dangerous microbes such as viruses, fungi, and pathogenic bacteria that linger on the surface and in the air for a long period are the main cause of contact with diseases affecting animals and humans, especially now with reinfections and cross contaminations. Studies show the application of disinfectants and biocides via dry mist significantly reduces the number of viable infectious pathogens both in the air as well as on surfaces. Virusjet produces super micro-droplets that float in the air for around *10 minutes after application, reaching the most inaccessible parts where conventional cleaning or spraying can’t reach. *for the timing to re enter the room please read safety instruction according to the chemical you use.
CBM – cubic meter is calculated by multiplying the length, width, and height of the area to disinfect. For example, if the length, height, and width of the area to disinfect are 2.3 meters, 1.4meters, and 2 meters respectively, the volume of the area to disinfect is 2.3 X 1.4 X 2.00 = 6.44 CBM.